How to Validate Form Generation Before E-Signing
How to Validate Form Generation Before E-Signing
Overview
When an e-signature workflow produces an unexpected result, first determine whether the issue is present in the generated form data or only appears later when the e-signature envelope is created.
Validating the form-generation step first can help isolate the problem and avoid troubleshooting multiple systems at the same time.
This guide describes a practical validation sequence for Quik! Forms Engine workflows.
Why Validate Before E-Signing?
A typical e-signature workflow can involve several stages:
- Quik! receives form IDs, prefill data, recipient settings, and other configuration.
- Quik! Forms Engine generates the form output.
- Signing data is generated for e-signature fields and recipients.
- An e-signature envelope is created.
- The e-signature provider displays the final documents and signing fields.
If you identify the first stage where the output becomes incorrect, troubleshooting becomes much more focused.
Step 1 - Reproduce the Form Generation Request
Reproduce the same request that is used by your application.
For HTML generation:
POST /rest/quikformsengine/qfe/execute/html
Use the same:
- form IDs
- prefill fields
- recipient settings
- e-signature configuration
- environment
- optional generation properties
When troubleshooting, avoid changing values until you have reproduced the original behavior.
Step 2 - Confirm the Request Succeeded
Review:
- HTTP status code
- Quik! error code and message, when present
- returned form IDs
- generated output
A successful API call confirms that the request was processed, but you should still verify that the generated content matches your expectations.
Step 3 - Inspect the Generated Form Output
Confirm that the generated form contains the expected:
- forms
- prefilled values
- checkbox/radio selections
- names and contact information
- form instances
- calculated or mapped values relevant to the workflow
If the generated form is already incorrect, focus troubleshooting on the execute/html request, form configuration, or prefill data before moving on to the e-signature request.
Step 4 - Generate PrintData and SignData When Needed
For workflows that require deeper validation, request generated data by including:
{
"GeneratePrintData": true,
"GenerateSignData": true
}
This allows you to inspect the document-generation data and the e-signature mapping data separately.
PrintData
Use PrintData to verify the structured form data and rendering information being generated.
SignData
Use SignData to verify recipient mappings and signing-field/tab information before the envelope is created.
Related guide:
Step 5 - Compare the Form Output with SignData
A useful comparison is:
|
Observation |
Where to investigate first |
|---|---|
|
Form value is wrong and SignData is also wrong |
Form-generation request, prefill data, or form configuration |
|
Form value is correct but SignData is wrong |
SignData generation or e-signature mapping |
|
Form output and SignData are correct, but envelope is wrong |
Envelope request or downstream e-signature behavior |
|
Call 1 fails before data is generated |
Request structure, authentication, configuration, or endpoint validation |
|
Call 1 succeeds and Call 2 fails |
Envelope request, authorization, required envelope settings, or downstream e-signature configuration |
This comparison identifies the earliest point where the actual result differs from the expected result.
Step 6 - Validate Recipient Data Separately
If the issue involves recipients, confirm:
- expected roles are present
- recipient names and email addresses are populated as expected
- signing order is correct
- send type is correct
- authentication settings are correct
- extra recipients are configured as intended
- document visibility settings are configured separately when documents need to be excluded
Recipient documentation:
How to Configure Recipient Settings
Document visibility documentation:
Configuring Document Visibility
Step 7 - Validate the Envelope Request
If form generation and signing data are correct, move to the request that creates the e-signature envelope.
For Direct to DocuSign, verify that:
- the correct
PrintDatais being passed - the correct
SignDatais being passed signSettingsis presentpackagesDatacontains the expected package or packages- the customer/account context is correct
- the expected environment is used
The Direct to DocuSign guide contains the current two-call flow and envelope request structure:
Step 8 - Use a Minimal Reproduction if Needed
If the request is large, create a smaller reproduction only after saving the full failing request.
Examples:
- one form instead of multiple forms
- one recipient instead of multiple recipients
- only the fields required to reproduce the problem
- one optional property at a time
The goal is to identify the smallest request that still shows the same behavior.
Example Troubleshooting Sequence
Suppose a checkbox appears selected on the generated form but is not selected in the e-signature envelope.
A useful sequence is:
- Confirm the submitted field value in the original request.
- Confirm the checkbox is selected in the generated form output.
- Inspect the related checkbox or radio information in
SignData. - If
SignDatais already incorrect, stop there and troubleshoot the generation step. - If
SignDatais correct, inspect the envelope request and final envelope behavior.
This approach avoids treating the entire workflow as one undifferentiated problem.
When Contacting Quik! Support
Provide:
- original sanitized
execute/htmlrequest - complete
execute/htmlresponse - generated output showing the expected or unexpected result
PrintDataandSignDatawhen relevant- downstream envelope request and response when relevant
- exact step where the expected and actual results first differ
- timestamp and time zone
Do not include OAuth tokens, passwords, or sensitive client information.